Pro-link Biobased Industrial Cleaner 12628 EN User Manual

Browse online or download User Manual for For Home Pro-link Biobased Industrial Cleaner 12628 EN. Pro-Link Biobased Industrial Cleaner 12628 EN User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
Biobased
Industrial Cleaner
NFPA/HMIS : Health -1
Flammability - 2
Reactivity - 0
Complies With USDL Safety and Health Regulations, (29 CFR 1910.200)
US Department Of Labor
Material Safety Data Sheet
SECTION - 1 CHEMICAL AND COMPANY
IDENTIFICATION
PRODUCT USE: Degreaser
Pro Link
500 Chapman Street
Canton, MA 02121
EMERGENCIES: 1-800-255-3924
REVISION DATE: 02/12/09
SECTION - 2 COMPOSITION ON INGREDIENTS
CAS # CHEMICAL NAMES Wt% TLV (UNITS)
5989-27-5 d-Limonene 95 NE
N/E = not established
SECTION - 3 HAZARDS INFORMATION
Primary Route(s) of Entry: Skin contact /absorption and inhalation
Signs and Symptoms of Overexposure: Gastrointestinal irritation
(nausea, vomiting, diarrhea), irritation to nose, throat, and respiratory tract.
Target Organ Effects: Overexposure to this material (or its components)
has been suggested as a cause of the following effects in laboratory
animals and may aggravate pre-existing disorders or these organs in
humans: chronic ingestion may cause kidney and liver lesions at high
doses.
IMMEDIATE HEALTH EFFECTS
EYES: Exposure may cause noticeable pain, and severe irritation and
transient corneal injury.
SKIN: Causes chemical burns. Harmful contact may not cause
immediate pain.
INHALATION: Exposure to vapor or mist is possible. Short term
inhalation is no likely to cause harmful effects:
breathing large amounts may be harmful. Symptoms are more typically
seen at air concentrations
exceeding the recommended exposure limits.
INGESTION: Harmful or fatal if swallowed. Causes chemical burns to
the mouth, throat and stomach.
REPRODUCTIVE / DEVELOPMENTAL INFORMATION
No Data
CARCINOGENIC INFORMATION: This material is not listed as a
carcinogen by IARC, NTP, or OSHA
LONG TERM EFFECTS: No Data
SECTION - 4 FIRST AID MEASURES
EYES: Immediately flush with water. Remove contact lenses, if
applicable, and continue flushing with water for 15 minutes. Call a
physician immediately.
SKIN: Immediately flush with water for 15 minutes. Call physician if
irritation persists. Completely decontaminate clothing, shoes, and leather
goods before reuse or discard.
INHALATION: If symptoms develop move victim to fresh air. If
symptoms persist, call a physician.
INGESTION: Do not induce vomiting. Rinse mouth with water, then drink
one or two glasses of water or milk. Call a physician immediately. Never
give anything by mouth if victim is unconscious, is rapidly losing
consciousness or is convulsing.
SECTION - 5 FIRE FIGHTING MEASURES
Flash Point: 122
o
F (C.C. method) Explosive Limits:
Not Applicable
Autoignition Temperature: Not Applicable
Hazardous Products of Combustion: Oxides of carbon, oxides of
nitrogen, and ammonia
Extinguishing Media: Not Applicable
Fire Fighting Instructions: Avoid contact with this material. Avoid
walking in spilled material. Wear protective clothing for skin and eyes
SECTION - 6 ACCIDENTAL RELEASE MEASURES
Small Spill: Absorb with an inert solid and scoop up for disposal, then
rinse soiled area with water down the drain.
Large Spill: Stop leak at the source and collect into a suitable container,
then treat as a small spill.
SECTION - 7 HANDLING AND STORAGE
Handling: Containers of this material may be hazardous when emptied.
Since emptied containers retain product residues (vapor, liquid, and/or
solid), all hazard precautions given in the data sheet must be observed.
Storage: Store in a cool, dry place. Keep container closed when not in
use.
SECTION - 8 EXPOSURE CONTROLS / PERSONAL
PROTECTION
Eye Protection: Chemical Splash goggle in compliance with OSHA
regulations are advised: however , OSHA regulations also permit other
type safety glasses. Consult your safety representative.
Skin Protection: Wear rubber gloves (consult your safety equipment
supplier). To prevent repeated or prolonged skin contact, wear
impervious clothing and boots.
Respiratory Protection: If workplace exposure limits of product or any
component are exceeded (see exposure guidelines), NIOSH/OSHA
approved air supplied respirator is advised in the absence of proper
environmental control. OSHA relations also permit other NIOSH/OSHA
respirators (negative pressure type) under specific conditions (see your
industrial hygienist). Engineering or administrative controls should be
implemented to reduce exposure.
Engineering Controls: Provide sufficient mechanical (general and local
exhaust) ventilation to maintain exposure below level of overexposure
(from known, suspected or apparent adverse effects).
SECTION - 9 PHYSICAL AND CHEMICAL
PROPERTIES
Appearance and odor: Thin, orange with a citrus odor
pH Concentrate: no applicable
Vapor Pressure: Unknown
Vapor Density: Unknown
Boiling Point: 212 Degrees Fahrenheit
Solubility in Water: none
Percent Volatile: 100
Specific Gravity: (H2O =1) 0.84 +/- 0.02
SECTION - 10 STABILITY AND REACTIVITY
Chemical Stability: Stable
Conditions to Avoid: Temperature Extremes
Incompatibility: Chlorine Bleach, Oxidizers, Acids
Hazardous Decomposition: Will not Occur
Hazardous Polymerization: Will not Occur
SECTION - 11 TOXICOLOGICAL INFORMATION
No Data Available
Page view 0
1 2

Summary of Contents

Page 1 - Industrial Cleaner

1 Biobased Industrial Cleaner NFPA/HMIS : Health -1 Flammability - 2

Page 2

2 SECTION - 12 ECOLOGICAL INFORMATION No Data Available SECTION - 13 DISPOSAL CONSIDERATION Waste Disposal Information: Dispose of in accordance with

Comments to this Manuals

No comments